Fluid Mechanics · worked example

Water at 3 m/s in 3-inch schedule 40 pipe

Frictional pressure drop and head loss for water flowing at 3 m/s through 50 m of 3-inch schedule 40 steel pipe (77.93 mm bore, ε = 0.045 mm).

Inputs

Inside diameter77.93 mm
Pipe length50 m
Velocity3 m/s
Density ρ998 kg/m³
Viscosity μ0.001 Pa·s
Roughness ε0.045 mm

Result

Pressure drop55.018 kPa
Pressure drop7.9797 psi
Head loss5.621 m fluid
Reynolds number233322
Flow regimeTurbulent
Friction factor (Darcy)0.01909

These values are computed by the Pipe Pressure Drop calculator. Open the tool to change any input.

Open the full Pipe Pressure Drop calculator →